HT33 series tower online three phase UPS offers advanced technology that increases performance and reliability: two (10 - 40kVA)/ three (60 - 500kVA) high speed DSPs with completed digital control fully ensure high quality of power supply, high input power factor and low input current distortion. It also offers humanization design: full front access of serviceability and user friendly interface.
The HT33 series 10 - 40kVA UPS is ideal for small load scenarios, and widely used in offices, health care, shopping centres and industrial factories. It has options for 10kVA, 15kVA, 20kVA, 30kVA, 40kVA, and supports 8 units parallel.
The HT33 series 60 - 500kVA UPS is a high stability and scalability product for medium and large data centers. The series has 60kVA, 80kVA, 90kVA, 100kVA, 120kVA, 150kVA, 200kVA, 250kVA, 300kVA, 400kVA, 500kVA options. It supports swappable power modules, with a maximum capacity of 500kVA in one cabinet but with a footprint less than 1.45m2.
HT33 Series 1- 40kVA Features:
HT33 Series 60 – 500kVA Features:
| Model | HT33010XL | HT33010XS | HT33015XL | HT33015XS | HT33020XL | HT33020XS | HT33030XL | HT33030XS | HT33040XL | HT33040XS |
| Main Input | ||||||||||
| Grid System | 3 Phases + Neutral + Ground | |||||||||
| Rated Input Voltage | 380/400/415VAC (Line-Line) | |||||||||
| Rated Frequency | 50/60Hz | |||||||||
| Input Voltage Range | 304~478Vac (Line-Line),full load; 228V~304Vac (Line-Line),load decreases linearly according to the min phase voltage | |||||||||
| Input Frequency Range | 40Hz~70Hz | |||||||||
| Input Power Factor | >0.99 | |||||||||
| Input Current THDi | <4% (full Linear Load) | <3% (full Linear Load) | ||||||||
| Bypass Input | ||||||||||
| Rated Bypass Voltage | 380/400/415VAC (Line-Line) | |||||||||
| Rated Frequency | 50/60Hz | |||||||||
| Bypass Voltage Range | Selectable, default -20%~+15%; Upper limit: +10%, +15%, +20%, +25%; Lower limit: -10%, -15%, -20%, -30%, -40% | |||||||||
| Bypass Frequency Range | Selectable, ±1Hz, ±3Hz, ±5Hz | |||||||||
| Bypass Overload | 125% Long term operation; 125%~130% for 10min; 130%~150% for 1min; | |||||||||
| Output | ||||||||||
| Rated Inverter Voltage | 380/400/415VAC (Line-Line) | |||||||||
| Rated Frequency | 50/60Hz | |||||||||
| Output Power Factor | 1 | 0.9 | ||||||||
| Voltage precision | ±1.5%(0-100% linear load) | |||||||||
| Transient Response | <5% for step load (20% – 80% -20%) | |||||||||
| Transient recovery | < 30ms for step load (20% – 100% -20%) | |||||||||
| Output Voltage THDu | <1% (linear load); <5.5% (non-linear load) according to IEC/EN62040-3 | <1% linear load; <6 (non-linear load) according to IEC/EN62040-3 | ||||||||
| Inverter Overload | <110%, 60min; 110%~125%,10min; 125%~150%,1min; | |||||||||
| Frequency Regulation | 50/60Hz±0.1% | |||||||||
| Synchronized Range | Settable, ±0.5Hz ~ ±5Hz, default ±3Hz | |||||||||
| Synchronized Slew Rate | Settable, 0.5Hz/S ~ 3Hz/s, default 0.5Hz/s | |||||||||
| Battery And Charger | ||||||||||
| Battery Rate Voltage | ±240VDC | |||||||||
| Charger Voltage precision | 1% | |||||||||
| Charger Power | max=20%Â System Power | |||||||||
| Efficiency | ||||||||||
| Normal Operation | 95%max | >95% | >96% | |||||||
| Battery Operation | 94.5%max | >95% | >96% | |||||||
| System | ||||||||||
| Display | LED + LCD | |||||||||
| Interface | Standard: RS232, RS485 Option: SNMP, Dry Contact, Parallel kit, Battery cold start | |||||||||
| Environmental | ||||||||||
| Operation Temperature | 0 ~ 40 ℃ | |||||||||
| Storage Temperature | -40 ~ 70 ℃ | |||||||||
| Relative Humidity | 0 ~ 95% (Non condensing) | |||||||||
| Noise (1 meter) | 58dB @ 100% load, 52dB @ 45% load | 65dB @ 100% load, 62dB @ 45% load | ||||||||
| Physical data | ||||||||||
| Dimension (W*D*H,mm) | 250*660*530 | 250*840*715 | 250*660*530 | 250*840*715 | 250*680*770 | 350*738*1335 | 250*680*770 | 350*738*1335 | 250*836*770 | 500*840*1400 |
| Weigh(Kg) | 31 | 51.5 (without battery) | 31 | 51.5 (without battery) | 50 | 89 (without battery) | 52 | 89 (without battery) | 61 | 140 |
| Model | HT33060X | HT33080X | HT33090X | HT33100X | HT33120X | HT33150X | HT33200X | HT33250X | HT33300X | HT33400X | HT33500X | ||
| System Capacity | 60kVA | 80kVA | 90kVA | 100kVA | 120kVA | 150kVA | 200kVA | 250kVA | 300kVA | 400KVA | 500KVA | ||
| Input | Dual Input | Standard | Optional | Standard | |||||||||
| Phase | 3 Phase+Neutral+Ground, 380V/400V/415V(line-line) | ||||||||||||
| Input Voltage Range | 304~478Vac (Line-Line),full load 228V~304Vac (Line-Line),load decrease linearly according to the min phase voltage | ||||||||||||
| Rated Frequency | 50/60Hz | ||||||||||||
| Input Frequency Range | 40Hz~70Hz | ||||||||||||
| Input PF | >0.99 | ||||||||||||
| Input THDi | <3% (100% Linear load) | ||||||||||||
| Bypass | Rate Voltage | 380/400/415Vac (Line-Line) | |||||||||||
| Rate Frequency | 50/60Hz | ||||||||||||
| Input Voltage Range | Settable, -40%~+25% | ||||||||||||
| Bypass Frequency Range | Settable, ±1Hz, ±3Hz, ±5Hz | ||||||||||||
| Bypass Overload | 125% long term operation 130% for 10 mins 150% for 1 min >150% for 300ms | 110% long term operation 125 % for 5 mins 150% for 1 min >150% for 1s | |||||||||||
| Output | Rate Voltage | 380/400/415Vac (Line-Line) | |||||||||||
| Voltage Regulation | Â 1% for balance load; 1.5% for unbalance load | ||||||||||||
| Rate Frequency | 50/60Hz | ||||||||||||
| Voltage Precision | 0.1% | ||||||||||||
| Output PF | 1 | ||||||||||||
| Output THDu | Â <1% , Linear load; <5.5%, Non-linear load | ||||||||||||
| Crest Factor | Â 3:1 | ||||||||||||
| Inverter Overload | Â 110% for 1 hour; 125% for 10 mins ;150% for 1 min; >150% for 200 ms | ||||||||||||
| Battery | Voltage | ±240Vdc | |||||||||||
| Battery Number | 40pcs (Settable: even number from 32 to 44) | ||||||||||||
| Voltage Precision | ±1% | ||||||||||||
| Charge Power | up to 20% * Output active power | ||||||||||||
| Battery Cold Start | Â Optional | Standard | |||||||||||
| System | Efficiency | AC Mode | Â 95% | Â 96% | Â 95% | Â 96% | Â 95% | Â 96% | |||||
| ECO Mode | Â 99% | ||||||||||||
| Battery Mode | Â 95% | Â 96% | Â 95% | Â 96% | Â 95% | Â 96% | |||||||
| Display | Â 10.4″(240kVA-500kVA) or 7”(60kVA-200kVA) touch screen LCD + LED + keyboard | ||||||||||||
| IP Class | IP 20 | ||||||||||||
| Interface | RS232,RS485, Programmable Dry Contact, USB | ||||||||||||
| Option | SNMP Card, Parallel kit, SPD, LBS, Dust filter | ||||||||||||
| Temperature | Operation: -40~70 ℃ | ||||||||||||
| Relative Humidity |  0~95% Non-condensing | ||||||||||||
| Altitude | Â <1000m. Within 1000m to 2000m, 1% power derating for every 100m rise | ||||||||||||
| Noise (1 meter) | 65dB @ 100% load, 62dB @ 45% load | ||||||||||||
| Applicable Standards | Â Safety: IEC/EN 62040-1Â EMC: IEC/EN 62040-2Â Performance: IEC/EN 62040-3 | ||||||||||||
| Physical | Weigh (kg) | 170 | 210 | 231 | 210 | 266 | 305 | 350 | 445 | 490 | 700 | 900 | |
| Dimension W*D*H (mm) | 600*980 *950 | 600*980 *1150 | 600*980 *1400 | 600*980 *1150 | 600*980 *1400 | 650*960 *1600 | 650*960 *1600 | 650*970 *2000 | 650*970 *2000 | 1050*1000 *2000 | 1300*1000 *2000 | ||
Directly record to SD cards or internal memory for weeks of continuous monitoring without data loss. [Placeholder text box for custom product feature highlights populated later]
Power Parameters is the official authorized Australian service and technical support facility. We provide traceable calibration, certified warranty repairs, scheduled maintenance, and genuine OEM parts from our climate-controlled laboratory in Westmeadows, Victoria, as well as on-site calibration across Australia.

Model: HT33 Series (10-500kVA)