HomeInstrumentationField TestingClamp MetersCM4373-50 AC/DC CLAMP METER 2000A AC/DC

CM4373-50 AC/DC CLAMP METER 2000A AC/DC

Specifications

True RMS 2000 A AC/DC Clamp Meter for the Toughest Situations

With DMM Functions that Deliver Top Safety

when Z3210 is installed

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4373-50 is a 2000 A True RMS clamp meter that features stronger jaws, IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment.

Key Features

  • CAT IV 600 V, CAT III 1000 V
    When using P2000: CAT III 2000 V, CAT IV 1000 V
  • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
  • Simultaneously measure inrush current in RMS and crest values
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
  • Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
  • Automatic AC/DC function helps boost work efficiency
  • *1:When using the optional DC High Voltage Probe P2000. The clamp meter itself is capable of measuring up to 1000 V DC.
  • *2:Wireless Adapter Z3210 is necessary.

Model No. (Order Code)

CM4373-50 Wireless Adapter Z3210 not included
CM4373-90 Bundled with the Wireless Adapter Z3210

Safe inspection of solar installations with high voltage

DC High V Probe Mode

– Enables high voltage measurement up to CAT III 2000 V
– Safely measure solar installations like the mega-solar without interrupting the grid by simply connecting the DC High Voltage Probe P2000 to compatible Hioki clamp meters and digital multimeters (DMMs)

See details about DC High Voltage Probe P2000

Wireless communication capability for even greater convenience

Wireless support

When the Wireless Adapter Z3210 is installed, Bluetooth® wireless communication is enabled. It transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings.

See details about Wireless Adapter Z3210

Excel® Direct Input Function (*1)

Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel®.

  • *1:The optional Wireless Adapter Z3210 is required.

Helping personnel analyze issues in the field

Harmonic measurement

When combined with GENNECT Cross (*2), you can perform simple harmonic analysis. Applications include problem analysis of power supply systems.

See here for details about GENNECT Cross

Problems that can be caused by harmonics

  • Equipment burn-out and destruction due to overheating
  • Malfunctions of power control devices
  • Increased loss along with reduced service life and efficiency for power devices
  • *2:GENNECT Cross is an free app that lets you connect field measuring instruments to smartphones and tablets using Bluetooth® communications. Wireless Adapter Z3210 (sold separately) is required in order to pair the instrument with GENNECT Cross.

Convenient for repeated measurement and recording tasks!

Automatic hold function

In addition to being convenient when the display cannot be seen during measurement, when the measurement value is stabilized, the display value is automatically held until the next measurement, which is very convenient for repeated measurement and recording tasks.

Assess transient currents at motor startup

The clamp meters can simultaneously measure inrush current in RMS as well as maximum crest values at motor startup and for welding currents.
The clamp meters automatically detect the duration of the inrush current (which can range from several dozen milliseconds to several hundred milliseconds) and measure the current during that interval, enabling them to yield more accurate
measurements than standard clamp-on meters whose measurement interval is fixed to 100 ms.

Product Resources
Datasheet How to Use the Hioki CM4370 Series Clamp Meters Enquire about this product
  • Equipment
  • SERVICE
  • CALIBRATION
  • New Tech
  • Knowledge
  • About
  • Contact

Copyright 2020 © Power Parameters Pty Ltd | Ph: 1800 623 350 | Fx: 1800 067 263
info@powerparameters.com.au. Further information may be found at suppliers website.
Sales Terms and Conditions

Clamp Meter Calibration | Data Logger Calibration | Electrical Mechanical Calibration | Electrical Tester Calibration | Encoder Repair | High Voltage Services | Hipot Tester Calibration | Insulation Resistance Tester Calibration | Insulation Tester Repairs | Multifunction Tester Calibration | Multimeter Calibration | Multimeter Repair | Power Supply Calibration | RCD Tester Calibration | Uninterruptible Power Supply | Voltmeter Calibration

1800 623 350

Connect with an electrical engineer for support, request an audit or report.

Scroll to top