CM4371-50 AC/DC CLAMP METER
True RMS 600 A AC/DC Clamp Meter for the Toughest Situations With DMM Functions that Deliver Top Safety

Product Description

True RMS 600 A AC/DC Clamp Meter for the Toughest Situations With DMM Functions that Deliver Top Safety when Z3210 is installed Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. Model CM4371-50 is a 600 A True RMS clamp meter that features stronger jaws, IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment.

CAT IV 600 V, CAT III 1000 V

*1: When using the P2010: CAT III 2000 V, CAT IV 1000 V

Safe inspection of solar installations with high voltage DC High V Probe (Optional)

  • Enables high voltage measurement up to CAT III 2000 V
  • Safely measure solar installations like the mega-solar without interrupting the grid by simply connecting the DC High Voltage Probe P2000 to compatible Hioki clamp meters and digital multimeters (DMMs)

Wireless communication capability for even greater convenience

When the Wireless Adapter Z3210 is installed, Bluetooth® wireless communication is enabled. It transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings.

Harmonic measurement

When combined with GENNECT Cross, you can perform simple harmonic analysis. Applications include problem analysis of power supply systems.

Problems that can be caused by harmonics

  • Equipment burn-out and destruction due to overheating
  • Malfunctions of power control devices
  • Increased loss along with reduced service life and efficiency for power devices

Assess transient currents at motor startup

The clamp meters can simultaneously measure inrush current in RMS as well as maximum crest values at motor startup and for welding currents. The clamp meters automatically detect the duration of the inrush current (which can range from several dozen milliseconds to several hundred milliseconds) and measure the current during that interval, enabling them to yield more accurate measurements than standard clamp-on meters whose measurement interval is fixed to 100 ms.

Technical Specifications

Key Features:

  • Measure DC voltages of up to 2000 V (When using the optional DC High Voltage Probe P2010) for open voltage inspections of solar panels
  • Simultaneously measure inrush current in RMS and crest values
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (Wireless Adapter Z3210 is necessary)
  • Harmonic analysis from 1st to 30th order with our free app GENNECT Cross (Wireless Adapter Z3210 is necessary)
  • Automatic AC/DC function helps boost work efficiency

Specifications:

DC Current range20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range)
AC Current range20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45-66 Hz: ±1.3% rdg. ±0.08 A (at 20 A)
Crest factor20.00 A range: 7.5
600.0 A range: 3 or less
DC+AC Current range20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±0.13 A (at 20 A)
DC Voltage range600.0 mV to 1000 V (When using P2010: 600.0 V to 2000 V)
AC Voltage range6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
DC+AC Voltage range6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
Resistance range600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Capacitance range1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency range9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
Temperature (K)-40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
Voltage detectionHi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
Harmonic levels[With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
Other functionsDC power, Continuity check, Diode check, Automatic AC/DC detection, Pass/fail judgement function of DC A and DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment
Dustproof, waterproofIP20 (Voltage measurement in a completely dry condition. When jaw closes)
IP54 (While in storage)
Power supplyLR03 Alkaline battery ×2
Continuous use: 40 hr (without Z3210 installed), 20 hr. (with Z3210 installed and using wireless communications)
Other conditions: 10 A AC measurement, backlight off, 23°C reference value
Core jaw diameterφ33 mm (1.30 in), Jaw dimension: 69 mm (2.72 in) W× 14 mm (0.55 in) D
Dimensions and mass65 mm (2.56 in) W × 215 mm (8.46 in) H × 35 mm (1.38 in) D mm, 340 g (12.0 oz)
Included accessoriesTest Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual×2, Operating Precautions ×1

Long-term Logging & Feature Highlights

Directly record to SD cards or internal memory for weeks of continuous monitoring without data loss. [Placeholder text box for custom product feature highlights populated later]

Official Australian Service & Calibration Partner

Calibration, Servicing & Warranty Support

Power Parameters is the official authorized Australian service and technical support facility. We provide traceable calibration, certified warranty repairs, scheduled maintenance, and genuine OEM parts from our climate-controlled laboratory in Westmeadows, Victoria, as well as on-site calibration across Australia.

Fast turnaround • Certificate included
Traceable Calibration Certificates
Genuine OEM Parts & Diagnostics
Fast 3–5 Day Turnaround
In-House Lab (VIC) & On-Site