Search
Home › Products ›
IR4057-50

Hioki IR4057-50

Hioki
IR4057-50 TESTER INSULATION DIGITAL 5 RANGE TO 1000V CAT III 600V
Quick Response Comparator Offering Reading Stability in High-speed Digital Format

Product Description

Hioki insulation testers or megohmmeters feature all-in-one designs including built-in rugged cases and test lead storage compartments. The IR4057-50 is a 5-range, 50V to 1000V digital insulation resistance tester with bargraph, and delivers efficient functions and features to help shorten work time associated with field insulation testing.

CAT III 600 V

Key Features:

  • Wireless support. Transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings. (Optional Wireless Adapter Z3210 is necessary)
  • Wirelessly transfer measurement data to Excel forms for input (Will be supported by the 2021 upgrade)
  • 5-range testing voltage of 50 V/100 MΩ to 1000 V/4000 MΩ
  • Digital bar graph
  • Stable & high-speed digital readings, 0.3 second response time for PASS/ FAIL decisions
  • Drop proof onto concrete from 1m (3.28 feet)
  • Bright LED, luminous LCD, test lead with bright LED lamp to illuminate near hand (Option L9788-11 or L9788-10)
  • Continuity check via 200 mA testing
  • Built in AC/DC voltage meter, useful for testing solar power generation systems and electric vehicles

Technical Specifications

Rated output voltage50 V DC125 V DC250 V DC500 V DC1000 V DC
Effective maximum indicated value100 MΩ250 MΩ500 MΩ2000 MΩ4000 MΩ
Accuracy
1st effective measuring range MΩ
±2 % rdg. ±2 dgt.
0.200 – 10.00
±2 % rdg. ±2 dgt.
0.200 – 25.0
±2 % rdg. ±2 dgt.
0.200 – 50.0
±2 % rdg. ±2 dgt.
0.200 – 500
±2 % rdg. ±2 dgt.
0.200 – 1000
Lower limit resistance0.05 MΩ0.125 MΩ0.25 MΩ0.5 MΩ1 MΩ
Overload protection600 V AC (10s)660 V AC (10s)
DC voltage range4.2 V (0.001 V resolution) to 600 V (1 V resolution), 4 ranges,
Accuracy: ±1.3% rdg. ±4 dgt., Input resistance: 100 kΩ or higher
AC voltage range420 V (0.1 V resolution) / 600 V (1 V resolution), 2 ranges, 50/60 Hz,
Accuracy: ±2.3% rdg. ±8 dgt., Input resistance: 100 kΩ or higher, Average rectifier
Low resistance rangeFor checking the continuity of ground wiring, 10 Ω (0.01 Ω resolution) to 1000 Ω (1 Ω resolution), 3 ranges, Basic accuracy: ±3 % rdg. ±2 dgt., testing current 200 mA or more (at 6 Ω or less)
DisplaySemi-transmissive FSTN LCD with back lighting, bar-graph indicator
Response timeApprox. 0.3 second for PASS/FAIL decision (based on in-house testing)
Other functionsIndicate MΩ measurement value after a lapse of one minute, Live circuit indicator, Automatic electric discharge, Automatic DC/AC detection, Comparator, Drop proof, Auto power save
Power supplyLR6 (AA) alkaline batteries × 4, Continuous use: 20 hours (based on in-house testing)
Number of measurements: 1000 times (at 5 s ON, 25 s OFF cycle, insulation measurement of lower limit resistance value to maintain nominal output voltage)
Dimensions and mass159 mm (6.26 in.) W × 177 mm (6.97 in.) H× 53 mm (2.09 in.) D, 640 g (22.6 oz.) (including batteries, excluding test leads)
Included accessoriesConnection cable L4930 ×1, Alligator clip set L4935 ×1, Test pin set L4938 ×1, Neck strap ×1, Instruction manual ×1, LR6 (AA) alkaline batteries ×4

Long-term Logging & Feature Highlights

Directly record to SD cards or internal memory for weeks of continuous monitoring without data loss. [Placeholder text box for custom product feature highlights populated later]

Official Australian Service & Calibration Partner

Calibration, Servicing & Warranty Support

Power Parameters is the official authorized Australian service and technical support facility. We provide traceable calibration, certified warranty repairs, scheduled maintenance, and genuine OEM parts from our climate-controlled laboratory in Westmeadows, Victoria, as well as on-site calibration across Australia.

Fast turnaround • Certificate included
Traceable Calibration Certificates
Genuine OEM Parts & Diagnostics
Fast 3–5 Day Turnaround
In-House Lab (VIC) & On-Site