Search
Home › Products ›
19056/19057

Chroma 19056/19057

Chroma
19056/19057 series Hipot Analyzer
Provides high withstand voltage test and analysis for optical couplers, HV relays, HV switches, and PV modules components, which have better insulation capability

Product Description

Chroma 19056/19057 Hipot Analyzer is an equipment specially designed for testing and analyzing ultra-high withstand voltage. The series of models include 10kVac/12kVdc/20kVdc with maximum AC20mA/DC10mA output can perform AC/DC withstand voltage and insulation resistance tests with contact check during production line test. In addition to the patented OSC (Open Short Check), High Voltage Contact Check is added to test the components with high insulation capability when high voltage outputs to improve the testing reliability and efficiency. Chroma 19056/19057 with GFI (Ground Fault Interrupt) is designed to protect operator’s safety when abnormal ground current (A2-A1) occurs.

The Hipot Analyzer provides high withstand voltage test and analysis for optical couplers, HV relays, HV switches and PV modules, which have better insulation capability. Charge and discharge are required for capacitive components when doing DC withstand voltage test. The Hipot Analyzers have fast charge function that can increase the production test efficiency . The Hipot Analyzer entire series has Flashover (ARC) detection function. Through the start voltage , end voltage, no. of steps and time, it can perform discharge level analysis. Phase judgment is provided in DLA (Discharge Level Analysis) mode to set inspection for Flashover (ARC) and Breakdown test (high limit). When a defect appears in the test, the 19056/19057 will show the withstanding voltage to indicate the Flashover Start Voltage (FSV) or BreakDown Voltage (BDV) respectively. In addition, External Oscilloscopes can be mounted to check the waveform at the same time during analysis. The R&D engineers can perform product analysis and study utilizing the test results to improve the weakness of insulation components.

Key Features:

  • 10kV AC & 20kV DC withstand voltage test
  • 0.1MΩ~50GΩ insulation resistance test
  • Breakdown Voltage test (BDV)
  • Flashover Detection (ARC)
  • High Voltage Contact Check (HVCC)
  • High Frequency Contact Check (HFCC)
  • Open Short Check (OSC)
  • Ground Fault Interrupt (GFI) for human protection circuit
  • Fast charge/discharge function
  • Programmable output & test limit
  • Standard USB, RS232 & HANDLER interfaces
  • Optional GPIB interface
  • CE Mark

Technical Specifications

Model Options:

ModelDescription
Guardian 19056Hipot Analyzer AC10KV
Guardian 19057Hipot Analyzer DC12KV (IR/BDV)
Guardian 19057-20Hipot Analyzer DC20KV (IR/BDV)
Accessories
A19035519″ Rack Mount Kit
A190356GPIB Interface for Model
A19070240kV High Voltage Testing Rod
A190708ARC (Flashover) Verification Fixture
10541Softpanel Kit

 

Product Resources

Long-term Logging & Feature Highlights

Directly record to SD cards or internal memory for weeks of continuous monitoring without data loss. [Placeholder text box for custom product feature highlights populated later]

Official Australian Service & Calibration Partner

Calibration, Servicing & Warranty Support

Power Parameters is the official authorized Australian service and technical support facility. We provide traceable calibration, certified warranty repairs, scheduled maintenance, and genuine OEM parts from our climate-controlled laboratory in Westmeadows, Victoria, as well as on-site calibration across Australia.

Fast turnaround • Certificate included
Traceable Calibration Certificates
Genuine OEM Parts & Diagnostics
Fast 3–5 Day Turnaround
In-House Lab (VIC) & On-Site