Camille Bauer CENTRAX CU3000 Multifunction Programmable Transducer with PLC function
Specifications
Flexible solutions for the energy industry
The CENTRAX CU3000 combines in one housing for panel mounting the functionality of a highly accurate measurement device for power applications with the possibilities of a freely programmable PLC according IEC 61131. Thus, in many cases, there is no need for a separate PLC, a control system, a remote display or an additional data collector.
The measurement part of the CU3000 determines in high quality more than 1500 state, energy consumption and power quality information. The control application (based on CODESYS) can then process these data logically, use them in control algorithms or respond to power generation or consumers in accordance with the application. The device can communicate with the process environment via freely selectable I/Os and via Modbus interfaces.
The Control functionality is provided in three performance classes: BASIC: Flexible processing of the data of the measurement device with full use of the I/O functionality ADVANCED: In addition, the possibility to read and use data from other measurement instruments via Modbus RTU/TCP, as well as to trigger time-depending processes PROFESSIONAL: For creating your own web visualization and to use the local display for self-defined visualizations Basic functionality Direct measurement up to 690V, CATIII Condition monitoring: class 0.1 (U/I), class 0.2 (P/Q/S) Energy consumption analysis, class 0.5S (meters, load profiles, trend analysis) Harmonic analysis acc. IEC 61000-4-7 System imbalance monitoring Universal process I/O Graphical measurement displays High resolution color TFT display Standard I/Os (1 digital input, 2 digital outputs) Ethernet interface Device parameterization via WEB browser Firmware update Measurement display Measurement acquisition via control system (Modbus/TCP server) ADVANCED function: Measurement acquisition from other devices (Modbus/TCP master) Service and maintenance
Options Modbus/RTU interface For measurement acquisition via control system (as slave) ADVANCED function: For measurement acquisition from other device (as master) Data logger Periodical data: Load profiles, meter readings Disturbance recorder: Recording of voltage events (acc. PQ standard IEC 61000-4-30) Events: Logbook of the occurrences of system events
Extensions Four extensions can be implemented in the device. You may select from: 2 relay outputs 2 analog outputs ±20mA 4 analog outputs ±20mA 4 S0 digital inputs active 4 S0 digital inputs passive Fault current detection Each fault current module provides two channels for monitoring differential or fault currents in earthed AC current systems. In any case measurement has to be performed via suitable current transformers, a direct measurement is not possible. Time synchronization via GPS Very accurate time synchronization of the measurement device using a preconfigured GPS receiver (accessory). Uninterrupted power supply (UPS) Provides power supply for five times 3 minutes if power fails IEC61850 interface Accessories Documentation on USB stick Current Transformers GPS receiver, configured
Product Resources
Copyright 2020 © Power Parameters Pty Ltd | Ph: 1800 623 350 | Fx: 1800 067 263
info@powerparameters.com.au.
Further information may be found at suppliers website.
Sales Terms and Conditions
Clamp Meter Calibration |
Data Logger Calibration |
Electrical Mechanical Calibration |
Electrical Tester Calibration |
Encoder Repair |
High Voltage Services |
Hipot Tester Calibration |
Insulation Resistance Tester Calibration |
Insulation Tester Repairs |
Multifunction Tester Calibration |
Multimeter Calibration |
Multimeter Repair |
Power Supply Calibration |
RCD Tester Calibration |
Uninterruptible Power Supply |
Voltmeter Calibration
Connect with an electrical engineer for support, request an audit or report.