IDCE-840CT Battery Discharger & Capacity Tester (with WX-2612)
Specifications
• Wide voltage range battery discharger: 10 V to 300 V
• 5.7 inch LCD touch screen for easy operation and showing various parameters real time
• Selectable discharge mode: constant current / power / resistanc
• 4 adjustable stop points and multiple alarm designs to control the discharge process intelligently
• Support RS232 real time monitoring by PC or USB download data after discharge
• PC software for capacity evaluation and report generation
• Optional wireless modules for 1.2V/2V/6V/12V cells voltage real-time measuring
Discharge Ranges
Voltage range current range
8-15V 0-60 A
18-30V 0-120 A
40-60V 0-120 A
70-140V 0-120 A
140-280V 0-60 A
Current measurement
Internal current range 0-120 A
Accuracy & resolution ≤±0.5%, 0.1 A
External current range 0-600 A(optional current clamp)
Accuracy & resolution ≤±1%, 0.1 A
Voltage measurement
Group voltage range 10-300 V
Accuracy & resolution ≤±0.5%, 0.1 V
Cell voltage range 0-15V
Accuracy & resolution ≤±0.5%, 0.01 V
Product Resources
Copyright 2020 © Power Parameters Pty Ltd | Ph: 1800 623 350 | Fx: 1800 067 263
info@powerparameters.com.au.
Further information may be found at suppliers website.
Sales Terms and Conditions
Clamp Meter Calibration |
Data Logger Calibration |
Electrical Mechanical Calibration |
Electrical Tester Calibration |
Encoder Repair |
High Voltage Services |
Hipot Tester Calibration |
Insulation Resistance Tester Calibration |
Insulation Tester Repairs |
Multifunction Tester Calibration |
Multimeter Calibration |
Multimeter Repair |
Power Supply Calibration |
RCD Tester Calibration |
Uninterruptible Power Supply |
Voltmeter Calibration
Connect with an electrical engineer for support, request an audit or report.