Delta DPH Series Modular UPS 75kVA/75kW with 25kVA/25kW Power Modules

Specifications

The modular UPS ideal for medium-sized datacenters

Introducing the next generation of modular uninterruptible power supply (UPS) systems designed for ultimate availability, excellent performance, high efficiency, and ideally suited for medium-sized datacenters.

The Modulon DPH Series UPS is a modular UPS used extensively for critical operations, since it provides 25% more power output compared to power factor 0.8 UPS systems. Designed for the most stringent datacenter requirements, the Modulon DPH Series offers the highest possible availability. With its modular structure, the true on-line, double conversion, three-phase Modulon DPH Series UPS system offers a scalable architecture for optimal power designs. It provides 25kW to 200kW of uninterruptible power with additional 800kW capacity in parallel.

The Modulon DPH Series’ scalable architecture is available in a 19″ enclosure, and supports vertical and horizontal expansion for versatile installation arrangements. Integration of your power distribution can take shape within the same rack or in parallel rack enclosures. Optimal placement is ultimately decided by the needs of the datacenter, not the limitations of the UPS system.

Built-in redundancy guarantees a continued power supply for mission critical applications, and the fully fault-tolerant design of the Modulon DPH Series offers self-redundancy for the control mechanism, cooling and power modules. Mean time to repair (MTTR) is close to zero, due to hot-swappable functionality for all critical components. In the event of failure by the main module, full control logic enables the system to self-synchronize and switch to the backup, for a seamless transition with no disruption to operations.

Delta’s Modulon DPH Series UPS provides one of the highest efficiency ratings in its class. With fully rated power, this modular 3 phase UPS delivers maximum power capacity, better power protection and quality to the load. Scalability, availability, and efficiency distinguish the Modulon DPH Series UPS as the best solution for power protection and distribution in your datacenters.

Ultimate Availability
Advanced fault-tolerant design achieved by self redundancy to guarantee operation continuity
Self-synchronization of power and control modules for continuous on-line operation even in the event of control module failure to avoid downtime caused by single point failure
Hot-swappable key modules and components to ensure Mean Time To Repair (MTTR) close to zero without downtime risk
Wide input voltage range of -45% to +25% and narrow output voltage regulation window to cope with harsh utility conditions and seamlessly provide stable power supply to the load
High overload protection to support 125% overload for 10 minutes and 150% for 1 minute
High Scalability
Vertical expansion from 25kW to 75/150/200kW supporting N+X redundancy in a single rack enclosure to save footprint
Parallel expansion up to four units without requiring additional hardware
Variable configurations possible providing the scalable flexibility up to Tier 4 standard
Excellent Power Performance and Efficiency
Fully rated power (kVA=kW) to maximize power availability
High AC-AC operating efficiency of 95% at 30% light load and 96% from 50% load resulting in marked energy cost savings
Low harmonic pollution (iTHD<3%) to reduce upstream investment costs and meet demanding power requirements
Easy Maintenance
Built-in manual bypass features to eliminate maintenance-related downtime
Proactive detection of fan failure and switch fault for early diagnosis on UPS malfunction
Plug and play to simplify the maintenance process
Product Resources
Enquire about this product
  • Equipment
  • SERVICE
  • CALIBRATION
  • New Tech
  • Knowledge
  • About
  • Contact

Copyright 2020 © Power Parameters Pty Ltd | Ph: 1800 623 350 | Fx: 1800 067 263
info@powerparameters.com.au. Further information may be found at suppliers website.
Sales Terms and Conditions

Clamp Meter Calibration | Data Logger Calibration | Electrical Mechanical Calibration | Electrical Tester Calibration | Encoder Repair | High Voltage Services | Hipot Tester Calibration | Insulation Resistance Tester Calibration | Insulation Tester Repairs | Multifunction Tester Calibration | Multimeter Calibration | Multimeter Repair | Power Supply Calibration | RCD Tester Calibration | Uninterruptible Power Supply | Voltmeter Calibration

1800 623 350

Connect with an electrical engineer for support, request an audit or report.

Scroll to top